Home /
Water Testing & Monitoring /
Handheld Meters /
Mirion RAD-60 LCD Radiation Detector Dosimeter
The RADOS RAD-60 Personal Alarming Dosimeter is a precise radiation measuring instrument for reliable detection and registration of radiation in order to ensure the personal safety of the user. It is suitable for a broad range of everyday radiation monitoring purposes in stand alone conditions.
Features:
- Enhanced EMI immunity
- Improved wear-out and decontamination properties
- Individual personal alarming dosimeter
- Digital display for integrated dose or alternatively dose rate
- User selectable alarm levels for both dose and dose rate
- Detector system utilizes high quality energy compensated Si diode and advanced mathematical dose rate linearization
- Splash-proof mechanical construction, high impact plastic case with strong pocket clip
- Ideal for civil defense, rescue operations, customs operations, military forces, industrial radiography, nuclear medicine
- Detects gamma and X-ray radiation
- Energy compensated Si-Diode detectors
- Measurement range:
- dose: 1 µSv - 9.99 Sv or 0.1 mrem - 999 rem
- dose rate: 5 µSv/h - 3 Sv/h or 0,5 mrem/h - 300 rem/h
- Calibration is better than ±5% (Cs-137, 662 keV at 2 mSv/h), Hp(10)
- Dose rate linearity is better than ±15%, up to 3 Sv/h (300rem/h)
- Energy response is Hp(10), 55 keV - 3 MeV, better than ±25%, up tp 6 MeV, better than ±35%
- Six preset alarm threshold values each for integrated dose and dose rate, manually selectable by push-button
- Front panel push-button functions:
- Toggle between dose and dose rate display
- Switch ON/OFF
- Chirp ON/OFF
- Reset integrated dose
- Change alarm thresholds
- Activate battery test
- Audible alarms:
- Seven separate alarms, sound level typically better than 85 dBA at 30 cm
- Low battery 1 and 2
- Defect
- Integrated dose, dose rate, dose overflow, dose rate overflow at 3 Sv/h or 300 rem/h
NOTE: Radiation meters are a special purchase item to address the needs of our customers and are non-refundable, with the exception of products that are not functioning due to manufacturer defects. Replacement for defective items must have trouble-shooting performed by our technical department prior to RGA approval.
California residents Prop 65 Warning
WARNING!
This product contains materials known to the State of California to cause
cancer and birth defects or other reproductive harm.
www.p65warnings.ca.gov
true">