The Pentair TLC-50 RO Membrane Element uses a state-of-the-art thin layer composite to provide high quality water from a wide range of water sources. Each membrane is packaged 100% dry for extended shelf-life and are built to standard dimensions so it will fit common membrane housings. The TLC-50 membrane is tested and certified by NSF/ANSI to standard 58.

Features:
  • Thin layer composite membrane
  • Provides high rejection stability even with high TDS input
  • 50 gallon per day membrane
  • Standard dimensions: 1.79" x 11.75" 
  • Nominal NaCL rejection: 98%
Tested and certified by NSF/ANSI to Standard 58 for the reduction of:
  • Arsenic
  • Barium
  • Cadmium
  • Chromium (Hexavalent)
  • Chromium (Trivalent)
  • Copper
  • Tubidity
  • Fluoride
  • Lead
  • Radium 226/228
  • Selenium
  • Total Dissolved Solids


Weight & Dimensions

Approx Length (Inches)

11.75 Inches

Details

Diameter

1.79 Inches

Flow Rate

50 Gallons per day

Material Of Construction

TLC (Thin Layer Composite)

Max Operating Pressure

100 PSI

Max Operating Temperature

120 Degrees Fahrenheit

Average Nacl Rejection

98 Percent

Chlorine Tolerance

0.1 Parts per Million

Direction

Outside - In

Membrane Type

Spiral Wound

Permeate Tube Diameter

0.68 Inches

Ph Range

4-11

Warranty & Certifications

Certifications

ANSI/NSF 58


Pentair





The Pentair TLC-50 RO Membrane Element uses a state-of-the-art thin layer composite to provide high quality water from a wide range of water sources. Each membrane is packaged 100% dry for extended shelf-life and are built to standard dimensions so it will fit common membrane housings. The TLC-50 membrane is tested and certified by NSF/ANSI to standard 58.

Features:
  • Thin layer composite membrane
  • Provides high rejection stability even with high TDS input
  • 50 gallon per day membrane
  • Standard dimensions: 1.79" x 11.75" 
  • Nominal NaCL rejection: 98%
Tested and certified by NSF/ANSI to Standard 58 for the reduction of:
  • Arsenic
  • Barium
  • Cadmium
  • Chromium (Hexavalent)
  • Chromium (Trivalent)
  • Copper
  • Tubidity
  • Fluoride
  • Lead
  • Radium 226/228
  • Selenium
  • Total Dissolved Solids

Weight & Dimensions

Approx Length (Inches)

11.75 Inches

Details

Diameter

1.79 Inches

Flow Rate

50 Gallons per day

Material Of Construction

TLC (Thin Layer Composite)

Max Operating Pressure

100 PSI

Max Operating Temperature

120 Degrees Fahrenheit

Average Nacl Rejection

98 Percent

Chlorine Tolerance

0.1 Parts per Million

Direction

Outside - In

Membrane Type

Spiral Wound

Permeate Tube Diameter

0.68 Inches

Ph Range

4-11