Use the chart below to identify the correct UV Bulb and quantity for your Wedeco or Ideal Horizons UV unit.
Model
Sleeve (Qty)
UV Lamp (Qty)
Flow Rate
Inlet / Outlet
SVE-4
QTZD005 (1)
LMP41004 (1)
4 GPM
¾" MPT
SVE-7
QTZD007 (1)
LMP41007 (1)
7 GPM
¾" MPT
SVE-10
QTZD007 (1)
LMP41007 (1)
10 GPM
¾" MPT
SVE-15
QTZD008 (1)
LMP41016 (1)
15 GPM
1" MPT
SVE-20
QTZD009 (1)
LMP41010 (1)
20 GPM
1" MPT
SVE-30
QTZD009 (1)
LMP41010 (2)
30 GPM
1.5" MPT
SVE-45
QTZD009 (3)
LMP41010 (3)
45 GPM
1.5" MPT
SVE-60
QTZD009 (4)
LMP41010 (4)
60 GPM
1.5" MPT
SSWE-6
QTZD005 (1)
LMP41004 (1)
6 GPM
¾" MPT
SSWE-10
QTZD007 (1)
LMP41007 (1)
10 GPM
¾" MPT
SSWE-15
QTZD008 (1)
LMP41016 (1)
15 GPM
1" MPT
SSWE-20
QTZD009 (1)
LMP41010 (1)
20 GPM
1" MPT
SSWE-30
QTZD009 (2)
LMP41010 (2)
30 G0M
1.5" MPT
SSWE-45
QTZD009 (3)
LM041010 (3)
45 GPM
1.5" MPT
SSWE-60
QTZD009 (4)
LMP41010 (4)
60 GPM
1.5" MPT
It is highly recommended to install a sediment prefilter (rated at 5 micron or less) before the Wedeco / Ideal Horizons UV unit to ensure that no sediment, algae, dirt, or other particles can shade the water. Viruses, bacteria and parasites can "hide" behind large particles and escape the UV light. We recommend the either the HD-950, or HF-360 as prefilters to UV systems: Click here to browse our Sediment Filters.
Safety and Efficiency NOTE:
Bare skin contact with the quartz envelope must be avoided. Compounds
from the skin when heated on lamps operating at 600 to 850˚c will form
permanent etching (devitrification) on the quartz surface, decreasing
UV energy transmission. A contaminated lamp eventually will overheat
causing premature failure. Alcohol wipes and rubber gloves are included
with every purchase of a quartz sleeve or lamp. NOTE: In case of
contact with bare skin, decontaminate lamp with alcohol wipe before
returning to use.